Particular Spec for Incinerator

The burner shall have all the necessary controls e.g.Solenoid valves, ignition controls, photo electric cell fuel safety controls, low pressure fuel supply cut-off etc.
Weight (kg), please indicate:
Secondary Chamber
Gas Retention Time – 2 Seconds
Diesel/LPG/LNG, please indicate
Power Supply for Control Box- 220V-240V 50Hz single phase
Burn Rate 250kg/h minimum
Weight (kg) please indicate:
Secondary Chamber
Gas Retention Time 2 Seconds
Fuel Diesel/LPG/LNG, please indicate
Power Supply for Control Box 220V-240V 50Hz single phase
Minimum operating temperature 920 °C, please indicate 
Lot 4 C High Temperature Waste Incinerator
Item 13 HTW Incinerator model D
Burn Rate – 150kg/hour minimum
Weight (kg), please indicate:
Secondary Chamber
Gas Retention Time 2 Seconds
Fuel Diesel/LPG/LNG, please indicate

The incinerator shall operate in an automatic manner with all the necessary controls.  These controls are to include safety elements such as flame failure unit, pilot lamps, fuses, starters, overload contactors, ON and OFF switches for burners and fans, combustion chamber temperature indicators for primary and secondary chambers etc.

i)  Electric ignition switch ‘ON’ before the oil is supplied
ii) Delayed return to re-start position to allow purging
iii) Re-start after temporary electric supply failure 
iv) Positive safety lock-out in case of flame failure from whatever cause.
v) Red signal light on control panel to indicate safety lock out
vi) Photo electric protective cell as flame failure device.

About the author: hiclover