Requirements and specifications for the process of supply, installation, operation and guarantee the three incinerators for burning and incineration of drugs and toxic substances for customs department

Incinerator 20 Kg Incinerator electrically operated including:  A cage for receipt of biomedical waste;  A combustion chamber with fireplace with a filter to retain ashes;  A cover;  An air supply; A turbine  allowing supply air.  Combustion temperature: 1800 ° C. Comes with all accessories •    Installing a readymade concrete base (Precast) with Height 30 cm above the ground and 20 cm below the surface of the earth. •    The dimensions of the base are increased by (2 meters) from the edge of incinerators •    The rest of the accessories in all the trends even allows the worker directly feeding and maintenance work, cleaning and move easily taking into account the tendencies of the base toward the door for drainage of water.•    The floor coating must be high-quality epoxy paint.•    Install anti-rust and heat Umbrella of brick and steel (pyramid shape) of (5) meters height above the ground which installed with the edge of the concrete base by thick galvanized columns •    This umbrella Cover the site furnace and allow bringing the chimney•   The site is surrounded by an iron fence (sheet metal) 3 meters height from the surface of the earth in order to protect the incinerators from dust storms •    The iron fence must have a 5 meters Width gate  •    Automatic anti-rust and heat electrical circuit must be provided •    The furnaces are highly efficient, emissions-free, safe, and environmentally friendly and have capacity of not less than 3,000 kg of materials and the rate of burning at least 400 kg / h•    The method of feeding the furnace through a side slot or from the top and the emission of the smoke is completely prevented.•    a furnace Must have two rooms, one of them is the  main room of not less than the “5” stoves to the process of burning materials and other secondary room of not less “2” stoves to burn resulting gas from the first process as well as the chimney•    The main component of the body of the furnace is stainless steel box, the thickness of not less than 7 mm with a layer of zinc phosphate plated with aluminium reflector to heat•     the thickness of the door of 150 mm and a hardness of not less than 170 kg / m 3 to be burnt, automatic comprehensive remote system.•    Furnaces must be destructive enough to burn and incinerate the material which mentioned previously •   furnaces must have certificates are supported global enterprises and government competent for environmental protection In the country of origin or the General Presidency of Meteorology and Environment Protection in Saudi Arabia•    The oven can work for 24 hours so as to allow for the burning of materials for a period of not less than 12 consecutive hours and the remainder for cooling and provides full fuel tank with a capacity of 1000 L to turn on the oven.•    Must have an automatic ignition and diesel is used•    a furnace has the ability to withstand extreme temperatures up to “130o c And also, it guarantees continuous operation of which can be utilized for 24 hours with the ability to remove residues during the work of the oven, Insulating layer of calcium must be present in the rooms with Thickness not less than 50 mm and a wall thickness of 100 mm •    Isolation of burning room: the space between the walls must be of the “stainless steel”. In addition, burn room must fill with Thermal insulation material.•    Ensure that the combustion of materials emitted in the secondary room should be at least two seconds period and the room is lined with high-density ceramic fibbers•    Incinerators must contain a system for processing (purification) gasses before emission of the smoke.•     Incinerators must have the capacity of self-cooling after the end of the daily operating period.•    Incinerators must have chimney not less than “4 meters” height from the surface of the oven, also, it must be thermally insulated and non-rust able, and must also be removable, installation and tide default.•    Electrical capacity required “220/ 380-volt “60 hertz•    Incinerators must be fitted with a control panel of the electronic keys to monitor all the necessary indicators of activation keys, as well as start-up and switch off so as to be isolated inside a metal box with the presence of the following:Alarm Sensor in the event of (crashes “burner” or purification device or heat leakage       or internal connections and wiring)Monitors for the temperature of the rooms Aerosols Filter indicators/ monitorsRoom temperature sensors Indicators for furnaces and index overloadTimer for Extinguish the oven automatically depending on the time required. •    All equipment must be highly resistant to external conditions such as high temperature (50oc) •    All doors must have special lock are not allowed non-persons appointed to work.•    Providing fire extinguisher for each site with a capacity of 10 kg at least

INCINERATOR For incineration of Laboratory wastes materials

i.Smoke and smell freeii.High Temperature , refractory lining with excellent heat retentioniii.Quick heat up timeiv.Must have a secondary chamberv.Constant run fanvi.Temperature monitoring vii.Thermostat Control Technical Specificationsi.Capacity :                    approx. 0.20 m3ii.Fuel consumption:        5 litres /hour Diesel Oiliii.Min Operating Temp:   900 oCiv.Max Operating Temp:   1350 oCv.Residence Time:           2 secvi.Burning rate:                 35kg/hr minimum 

INCINERATOR For incineration of Laboratory wastes materials

i.Smoke and smell freeii.High Temperature , refractory lining with excellent heat retentioniii.Quick heat up timeiv.Must have a secondary chamberv.Constant run fanvi.Temperature monitoring vii.Thermostat Control Technical Specificationsi.Capacity :                    approx. 0.20 m3ii.Fuel consumption:        5 litres /hour Diesel Oiliii.Min Operating Temp:   900 oCiv.Max Operating Temp:   1350 oCv.Residence Time:           2 secvi.Burning rate:                 35kg/hr minimum 

Biomedical Waste Incinerator, 10-15 KG 

The Biomedical Waste Incinerator is used for Incineration of each type of Biomedical Waste.The Disposal of such Biomedical waste is a very important as it is a dangerous wastes forhuman life, and It is only possible with a perfect incinerator.Operational RequirementsIt shall be operated by manual and automated mode.The combustion efficiency (CE) shall be at least 99.00%.The combustion efficiency is computed as follows:C.E.= __%CO2______ x 100%CO2 + %COEmission Standards: Lower emission rates are preferred.Parameters                   Concentration in mg/Nm3 (12% CO2 correctionMax total dust              30mg/m3Max Sulphur Dioxide      200mg/m3Max Nitrogen dioxide    400mg/m3Max Carbon                     100mg/m3MonoxideMinimum stack height shall be 30 metres above ground.Volatile organic compounds in ash shall not be more than 0.01%.System ConfigurationBiomedical Waste Incinerator, complete unit.Technical SpecificationsIncinerator:It shall be Electrical or Diesel Fired Incinerator or Controlled Air & pyrolytic.Type of Waste: Biomedical WasteIt shall have burning capacity 10-15 kg/hr.Fuel: DieselBurner: Monoblock fully automatic burners.Temperature: Primary Chamber 800 ± 50 oC, Secondary Chamber 1050 ± 50 oC.Type of Waste: Biomedical waste with moisture content up to 85%.Destruction Efficiency: 99%.It shall have separate digital display of temperature for both chambers.It shall have provision for measuring primary & secondary chamber temperatures using externalthermo coupler.

Biomedical Waste Incinerator, 10-15 KG 

The Biomedical Waste Incinerator is used for Incineration of each type of Biomedical Waste.The Disposal of such Biomedical waste is a very important as it is a dangerous wastes forhuman life, and It is only possible with a perfect incinerator.Operational RequirementsIt shall be operated by manual and automated mode.The combustion efficiency (CE) shall be at least 99.00%.The combustion efficiency is computed as follows:C.E.= __%CO2______ x 100%CO2 + %COEmission Standards: Lower emission rates are preferred.Parameters                   Concentration in mg/Nm3 (12% CO2 correctionMax total dust              30mg/m3Max Sulphur Dioxide      200mg/m3Max Nitrogen dioxide    400mg/m3Max Carbon                     100mg/m3MonoxideMinimum stack height shall be 30 metres above ground.Volatile organic compounds in ash shall not be more than 0.01%.System ConfigurationBiomedical Waste Incinerator, complete unit.Technical SpecificationsIncinerator:It shall be Electrical or Diesel Fired Incinerator or Controlled Air & pyrolytic.Type of Waste: Biomedical WasteIt shall have burning capacity 10-15 kg/hr.Fuel: DieselBurner: Monoblock fully automatic burners.Temperature: Primary Chamber 800 ± 50 oC, Secondary Chamber 1050 ± 50 oC.Type of Waste: Biomedical waste with moisture content up to 85%.Destruction Efficiency: 99%.It shall have separate digital display of temperature for both chambers.It shall have provision for measuring primary & secondary chamber temperatures using externalthermo coupler.

Smaller animal cremators incinerator

Smaller cremators that will run diesel and will be capable of doing all the other dogs/cats/pets that we have. We only cremate pets individually so this is what we require. Have your company as member of Markis Hospital waste management group as planer or supplier, contractor of solutions or operating partners of the solution of hospital waste management in the projects we are developing, starting with Larissa and Volos. Members of Markis waste management group will also have the possibility to provide training and technical services to the health sector of Greece and other countries via the TSC which we plan to make the same time in Larissa (enclosed diagram indicates the role of each party joining Markis waste management group). ● Able to burn 25-30kg per hour ● Consist of two chambers to ensure significant reduction in emission ● Be capable of temperature in range of 800c to 1000c ● Low maintenance design ● Must be Diesel fuelled ● Need more than 15amp 220- 250V power ● kW Consumption power consumption to be stated ● Onboard or in-built fuel storage storage tank & should use no more than 12L of dies el per hour to burn 25-30kg of waste ● Solid waste reduction in range of 90-97% ( should be routinely achieved) 1. –  2 medical waste autoclaves 350ltr and 100ltr 2. – 1 medical waste shredder 3. –  3 medical macerators 4. – 27 Waste transfer trolleys.

Smaller animal cremators incinerator

Smaller cremators that will run diesel and will be capable of doing all the other dogs/cats/pets that we have. We only cremate pets individually so this is what we require. Have your company as member of Markis Hospital waste management group as planer or supplier, contractor of solutions or operating partners of the solution of hospital waste management in the projects we are developing, starting with Larissa and Volos. Members of Markis waste management group will also have the possibility to provide training and technical services to the health sector of Greece and other countries via the TSC which we plan to make the same time in Larissa (enclosed diagram indicates the role of each party joining Markis waste management group). ● Able to burn 25-30kg per hour ● Consist of two chambers to ensure significant reduction in emission ● Be capable of temperature in range of 800c to 1000c ● Low maintenance design ● Must be Diesel fuelled ● Need more than 15amp 220- 250V power ● kW Consumption power consumption to be stated ● Onboard or in-built fuel storage storage tank & should use no more than 12L of dies el per hour to burn 25-30kg of waste ● Solid waste reduction in range of 90-97% ( should be routinely achieved) 1. –  2 medical waste autoclaves 350ltr and 100ltr 2. – 1 medical waste shredder 3. –  3 medical macerators 4. – 27 Waste transfer trolleys.

Specifications for Double Chamber and Mobile Incinerator

Specifications for Double Chamber Incinerator: Primary Combustion ・ The primary combustion chamber shall be accepted as the primary combustion zone. ・ The minimum combustion temperature of the primary chamber shall not be less than 800 degrees c Secondary Combustion ・ The residence time in the secondary chamber shall not be less than 2 seconds ・ The gas temperature as […]

Specifications for Double Chamber and Mobile Incinerator

Specifications for Double Chamber Incinerator: Primary Combustion ・ The primary combustion chamber shall be accepted as the primary combustion zone. ・ The minimum combustion temperature of the primary chamber shall not be less than 800 degrees c Secondary Combustion ・ The residence time in the secondary chamber shall not be less than 2 seconds ・ The gas temperature as […]

Technical specification for burning incinerator machine

17.The primary burning room  should have at least 2 burners. 18.The secondary burning room should have one burner. 19.  Each system should have doors for ash, exit for air to the chimney and windows to allow looking inside and for maintenance. 20.Each system should have filtering system for gas processing with 2 tanks using ordinary water. Each water tank should have capacity of 1000  lt and should be fixed to the system and provided with water level indicator. 21.Each system should have special technology for separating waist products and humidity after gas processing. 22.Each system should have cooling capability after operation. 23.Each system m should be provided with exhaust pipe with 250 mm diameter and 10 m high. The base of the exhaust system should be 1000 mm.  The exhaust pipe should be 6 mm and should be provide with heat insulator.  The exhaust system should be provided with pressure indicator. It  should also provide with ladder and Lightning Arrestor. 24.Electric power: should be 220 volt, 3 phase, 60 Hz, and the motor should not be less than 15 HP. 25.Each system should be provided with control panel and indicators and needed safety equipment and alarm systems. The control panel should  show at least temperature in both the primary and secondary rooms and injectors of the filters and load.    26.Each system should be provided with alarm system for any breakdown or defect of any component of the system. 27.The following personal protective tools must be provide: a.Heat resistant garments for 20 persons. b.Heat resistant goggles for 20 persons. 28.All components of each system should be painted with silver color that is heat resistant.