HICLOVER

Medical Waste Incinerator System|Containerized Mobile Incinerator|Pet Cremation Equipment

    

About

Medical |Environmental|Pet Animal

We supply single combustion chamber, double combustion chambers, three combustion chambers and multi-combustion chambers waste incinerators for laboratory, clinic, hospital, medical center, hygiene clinical waste destruction with medical disposable, biological waste, medical plastic waste, hazardous waste, red bag waste, needle disposal, gauze and bandages, sealed sharp containers, pathological waste, trace-chemotherapeutic wastes, etc.

HICLOVER®

Economized Small Scale Incinerator

Economized Small Scale Incinerator

Single Combustion Chamber,Three Combustion Chambers

Medical Waste Incinerator

Medical Waste Incinerator

Middle-Small Capacity,Large-Middle Capacity

Pet and Animal Cremation Incinerator

Pet and Animal Cremation Incinerator

Pet Cremation Equipment,Animal Cremation Equipment

General Waste Incinerator

General Waste Incinerator

Municipal Solid Waste

Featured Waste Incinerator

Featured Waste Incinerator

Containerized Mobile Incinerator,High Efficient Environmental Protection Incinerator(Wet Scrubber)

Customer Made Waste Incinerator

Customer Made Waste Incinerator

Customer Made

Voice from Client

Email: sales@hiclover.com|Tel: +86-25-8461 0201

Contact Us

HICLOVER

HICLOVER, Nanjing Clover Medical Technology Co.,Ltd, supply system solutions for medical environmental protection, animal and pet cremation engineering, other municipal solid waste incineration project.We are china incinerator manufacturer, contractor and exporter. Manufacturer make reasonable price for incinerator customer, supply medical incinerator, hospital incinerator, animal incinerators, hog incinerators, pet cremation equipment, small incinerator, pet incinerator, animal incinerator, portable incinerator, small animal incinerator, infectious waste pyrolysis machine, laboratory incinerator. HICLOVER help customer reduce purchase budget, custom made function, quality products and friendly service.HICLOVER is growing brand for environmental protection field, and market share with most of Africa, Middle East, Southeast Asia countries and part of North America, Europe territory. We are trusted partner for governmental organizations, non-profit organizations, international contractors, logistics organizations, military, pet cremation business owners, etc. We have export experience more than 40 countries, including war zone like Iraq, Afghanistan, Somalia, South Sudan.

Contact Info

  •   +86-25-8461 0201
  •   Rm.2-1704, North Wanhuicheng, No.28 Pukou Rd., Nanjing, China 211800
  •   sales@hiclover.com
200
Clients
98
Coutries
360
Projuects
450
Sales
Full range incinerator with Economized Small Scale incinerator, Standard Small-Large Scale incinerator, General Municipal Solid Waste Incinerator, Pet and Animal Cremation, Containerized Mobile Incinerator, High Efficient Environmental Waste Incinerator.
Product Range

Product Range

Single combustion chamber, double combustion chambers, three combustion chambers and multi-combustion chambers waste incinerators.
Key Features

Key Features

System solutions for medical waste environmental.
Solutions

Solutions

BLOG

Technical specification for burning incinerator machine

17.The primary burning room  should have at least 2 burners. 18.The secondary burning room should have one burner. 19.  Each system should have doors for ash, exit for air to the chimney and windows to allow looking inside and for maintenance. 20.Each system should have filtering system for gas processing with 2 tanks using ordinary water. Each water tank should have capacity of 1000  lt and should be fixed to the system and provided with water level indicator. 21.Each system should have special technology for separating waist products and humidity after gas processing. 22.Each system should have cooling capability after operation. 23.Each system m should be provided with exhaust pipe with 250 mm diameter and 10 m high. The base of the exhaust system should be 1000 mm.  The exhaust pipe should be 6 mm and should be provide with heat insulator.  The exhaust system should be provided with pressure indicator. It  should also provide with ladder and Lightning Arrestor. 24.Electric power: should be 220 volt, 3 phase, 60 Hz, and the motor should not be less than 15 HP. 25.Each system should be provided with control panel and indicators and needed safety equipment and alarm systems. The control panel should  show at least temperature in both the primary and secondary rooms and injectors of the filters and load.    26.Each system should be provided with alarm system for any breakdown or defect of any component of the system. 27.The following personal protective tools must be provide: a.Heat resistant garments for 20 persons. b.Heat resistant goggles for 20 persons. 28.All components of each system should be painted with silver color that is heat resistant.

SPECIFICATIONS OF THE JKUAT INCINERATOR

SPECIFICATIONS OF THE JKUAT INCINERATOR It should  be  a three chambered incinerator  The load capacity of 250 kg The housing for the incinerator should be able to withstand the temperatures and other operational requirements. The chimney should have a strong refractory lining of special type of cement to withstand temperatures more than 1200oc. It should have a strong base for the machine to keep it stable, firm and secure during its operational lifespan. The primary (combustion) and the secondary (scorching) chambers to be fitted with burners for effective combustion. In the third chamber, scrubbers and precipitators will need to be installed as pollution control equipment before emission of gases into the atmosphere. A system for continuous emission Monitoring and Environmental Monitoring. A mechanism with which to treat the waste water before discharge into the sewerage system. Temperature control and monitoring devices (probe thermometer) should be availed to ensure that the right temperatures are attained in the chambers during operation. Motor (fans) sufficient to induce enough air into the combustion chambers and direct the gases towards the flue 9 chimney). High power electricity and emergency generator connection for automated ignition purposes. The chimney should be tall enough and be at least one meter above the tallest building in the vicinity. The fuel tank (industrial diesel) to be constructed next to but out side the incinerator housing for security purposes and to prevent fire hazards. Capacity of 250. Other Requirements Training of all the personnel involved in health care waste (HCW) management. The Automatic Feeding system of the Incinerator Automatic waste loading mechanism with conveyor belts. These will lead the waste into the first primary chamber. An Automatic bottom ashes discharge system.

Hot Medical Waste Disposing Machine Burn rate per hour: 250 -300kg/hr

Incinerator should be smokeless, odourless combustion and it should be made by high-quality cast, insulation, and steel plate as well as minimum generation of dust. Moreover the incinerator should be corrosion resistant.    Type Pyrolytic:- Hot Medical Waste Disposing Machine   Operation Condition 8-16 Hr /day Controls Built in data recording Incinerator /Primary Combustion Chamber Type: continuous loading Capacity/Burn rate per hour: 250 -300kg/hr Temperature:  900-1200 oC   Material: External- 3 layers Internal lining:  a fire proof material of pre-fired refractory bricks with Aluminium lining, resistant to corrosive waste or […]