HICLOVER

Medical Waste Incinerator System|Containerized Mobile Incinerator|Pet Cremation Equipment

    

About

Medical |Environmental|Pet Animal

We supply single combustion chamber, double combustion chambers, three combustion chambers and multi-combustion chambers waste incinerators for laboratory, clinic, hospital, medical center, hygiene clinical waste destruction with medical disposable, biological waste, medical plastic waste, hazardous waste, red bag waste, needle disposal, gauze and bandages, sealed sharp containers, pathological waste, trace-chemotherapeutic wastes, etc.

HICLOVER®

Economized Small Scale Incinerator

Economized Small Scale Incinerator

Single Combustion Chamber,Three Combustion Chambers

Medical Waste Incinerator

Medical Waste Incinerator

Middle-Small Capacity,Large-Middle Capacity

Pet and Animal Cremation Incinerator

Pet and Animal Cremation Incinerator

Pet Cremation Equipment,Animal Cremation Equipment

General Waste Incinerator

General Waste Incinerator

Municipal Solid Waste

Featured Waste Incinerator

Featured Waste Incinerator

Containerized Mobile Incinerator,High Efficient Environmental Protection Incinerator(Wet Scrubber)

Customer Made Waste Incinerator

Customer Made Waste Incinerator

Customer Made

Voice from Client

Email: [email protected]|Tel: +86-25-8461 0201

Contact Us

HICLOVER

HICLOVER, Nanjing Clover Medical Technology Co.,Ltd, supply system solutions for medical environmental protection, animal and pet cremation engineering, other municipal solid waste incineration project.We are china incinerator manufacturer, contractor and exporter. Manufacturer make reasonable price for incinerator customer, supply medical incinerator, hospital incinerator, animal incinerators, hog incinerators, pet cremation equipment, small incinerator, pet incinerator, animal incinerator, portable incinerator, small animal incinerator, infectious waste pyrolysis machine, laboratory incinerator. HICLOVER help customer reduce purchase budget, custom made function, quality products and friendly service.HICLOVER is growing brand for environmental protection field, and market share with most of Africa, Middle East, Southeast Asia countries and part of North America, Europe territory. We are trusted partner for governmental organizations, non-profit organizations, international contractors, logistics organizations, military, pet cremation business owners, etc. We have export experience more than 40 countries, including war zone like Iraq, Afghanistan, Somalia, South Sudan.

Contact Info

  •   +86-25-8461 0201
  •   Rm.2-1704, North Wanhuicheng, No.28 Pukou Rd., Nanjing, China 211800
200
Clients
98
Coutries
360
Projuects
450
Sales
Full range incinerator with Economized Small Scale incinerator, Standard Small-Large Scale incinerator, General Municipal Solid Waste Incinerator, Pet and Animal Cremation, Containerized Mobile Incinerator, High Efficient Environmental Waste Incinerator.
Product Range

Product Range

Single combustion chamber, double combustion chambers, three combustion chambers and multi-combustion chambers waste incinerators.
Key Features

Key Features

System solutions for medical waste environmental.
Solutions

Solutions

BLOG

Particular Spec for Incinerator

The burner shall have all the necessary controls e.g.Solenoid valves, ignition controls, photo electric cell fuel safety controls, low pressure fuel supply cut-off etc.Weight (kg), please indicate:Secondary ChamberGas Retention Time – 2 SecondsDiesel/LPG/LNG, please indicatePower Supply for Control Box- 220V-240V 50Hz single phaseBurn Rate 250kg/h minimumWeight (kg) please indicate:Secondary ChamberGas Retention Time 2 SecondsFuel Diesel/LPG/LNG, please indicatePower Supply for Control Box 220V-240V 50Hz single phaseMinimum operating temperature 920 °C, please indicate Lot 4 C High Temperature Waste IncineratorItem 13 HTW Incinerator model D Burn Rate – 150kg/hour minimum Weight (kg), please indicate: Secondary Chamber Gas Retention Time 2 Seconds Fuel Diesel/LPG/LNG, please indicate The incinerator shall operate in an automatic manner with all the necessary controls.  These controls are to include safety elements such as flame failure unit, pilot lamps, fuses, starters, overload contactors, ON and OFF switches for burners and fans, combustion chamber temperature indicators for primary and secondary chambers etc. i)  Electric ignition switch ‘ON’ before the oil is suppliedii) Delayed return to re-start position to allow purgingiii) Re-start after temporary electric supply failure iv) Positive safety lock-out in case of flame failure from whatever cause.v) Red signal light on control panel to indicate safety lock outvi) Photo electric protective cell as flame failure device.

TECHNICAL SPECIFICATIONS FOR THE INCINERATOR

1. SCOPE OF WORK The work specified in the contract will include. 1. Supply, install and commission an incinerator as provided in the technical specifications 2. Provision for adherence to OSHA and other statutory requirement relating to Health and Safety of workers during execution of the works covered in this tender. 3. Assessment and preparation and construction of a standard incinerator shed with one waste storage room ( see the design )  4. Provision of operation and maintenance manuals and drawings complete with maintenance schedule and instructions.  5. Fuel oil storage tank- Mild steel1500 liters capacity  6. Onsite training for operation and maintenance staff.  auto on/off burner Auto temperature-excess air blower fanChamber constructed of two layer refractory lining, compressing:Thermal insulator lining & refractory masonry lining sufficient enough to maintain normal temperature at outsideControl PanelStandard PLC ControlNote: All the instruments/controllers must be of high quality. Preferably European/Japanese originChimnery/Stack-Made of MS Sheet. Sufficiently insulated & lined with refractory bricks(where required) to maintain normal temperature at outer surface-painted with high quality-customer will be responsible for provision of electric supply and natural gas uot in incineratorHeat and corrosion resistant paint.Note:Motors of all blowers/fans/pumps must be high quality, preferably imported(Japanese. European std)

WASTE INCINERATORS RECOMMENDATIONS

Incinerate minimum 80kg/hr X 12 hrs per dayDisposal of both non-hazardous and hazardous waste streams (per waste inventory)Mobile Unit (Skid mounted preference with lifting points)Design/SpecificationsIncinerators must have a secondary combustion chamber with a minimum temperature range of 900cLiquid waste streams shall be incinerated by an appropriate liquid injection systemThe incinerators will be installed with visual alarms to alert operations of low temperature in the secondary chamberOperating Environment and Ambient Conditions The Incinerators package shall be designed to operate under the following conditions:Average Daily Max/Min June Temperature, 21-39°CAverage Daily Max/Min January Temperature, 2-12°C