HICLOVER

Medical Waste Incinerator System|Containerized Mobile Incinerator|Pet Cremation Equipment

    

About

Medical |Environmental|Pet Animal

We supply single combustion chamber, double combustion chambers, three combustion chambers and multi-combustion chambers waste incinerators for laboratory, clinic, hospital, medical center, hygiene clinical waste destruction with medical disposable, biological waste, medical plastic waste, hazardous waste, red bag waste, needle disposal, gauze and bandages, sealed sharp containers, pathological waste, trace-chemotherapeutic wastes, etc.

HICLOVER®

Economized Small Scale Incinerator

Economized Small Scale Incinerator

Single Combustion Chamber,Three Combustion Chambers

Medical Waste Incinerator

Medical Waste Incinerator

Middle-Small Capacity,Large-Middle Capacity

Pet and Animal Cremation Incinerator

Pet and Animal Cremation Incinerator

Pet Cremation Equipment,Animal Cremation Equipment

General Waste Incinerator

General Waste Incinerator

Municipal Solid Waste

Featured Waste Incinerator

Featured Waste Incinerator

Containerized Mobile Incinerator,High Efficient Environmental Protection Incinerator(Wet Scrubber)

Customer Made Waste Incinerator

Customer Made Waste Incinerator

Customer Made

Voice from Client

Email: [email protected]|Tel: +86-25-8461 0201

Contact Us

HICLOVER

HICLOVER, Nanjing Clover Medical Technology Co.,Ltd, supply system solutions for medical environmental protection, animal and pet cremation engineering, other municipal solid waste incineration project.We are china incinerator manufacturer, contractor and exporter. Manufacturer make reasonable price for incinerator customer, supply medical incinerator, hospital incinerator, animal incinerators, hog incinerators, pet cremation equipment, small incinerator, pet incinerator, animal incinerator, portable incinerator, small animal incinerator, infectious waste pyrolysis machine, laboratory incinerator. HICLOVER help customer reduce purchase budget, custom made function, quality products and friendly service.HICLOVER is growing brand for environmental protection field, and market share with most of Africa, Middle East, Southeast Asia countries and part of North America, Europe territory. We are trusted partner for governmental organizations, non-profit organizations, international contractors, logistics organizations, military, pet cremation business owners, etc. We have export experience more than 40 countries, including war zone like Iraq, Afghanistan, Somalia, South Sudan.

Contact Info

  •   +86-25-8461 0201
  •   Rm.2-1704, North Wanhuicheng, No.28 Pukou Rd., Nanjing, China 211800
200
Clients
98
Coutries
360
Projuects
450
Sales
Full range incinerator with Economized Small Scale incinerator, Standard Small-Large Scale incinerator, General Municipal Solid Waste Incinerator, Pet and Animal Cremation, Containerized Mobile Incinerator, High Efficient Environmental Waste Incinerator.
Product Range

Product Range

Single combustion chamber, double combustion chambers, three combustion chambers and multi-combustion chambers waste incinerators.
Key Features

Key Features

System solutions for medical waste environmental.
Solutions

Solutions

BLOG

hospital waste management Incinerator system

Incinerator (hospital waste management system) is a turn-key project which will comprise a  hospital grade incinerator, allied accessories and operation for proper disposal of hospital General medical waste (plastics, gloves and papers) and Infectious waste (blood-soaked bandages, sharps waste, surgical waste, human or body parts, cultures, and swabs).the unit should be of high performance to operated continuously for at-least 12 hours daily. Energy/Fuel Source for incinerator will be Natural Gas based on Pyrolysis with smokeless emission, for ensuring the clean environment system should strictly comply with Environmental Protection Agency (EPA) Pakistan emission standards.   Technical Specifications:   1. Burning Capacity i. Incinerator should be capable to burn waste @ 100 kg / hr in single loading. 2. Construction i.   Packaged type skid mounted dual chamber construction ii. Stainless steel or Mild steel outer with thickness 5mm or more, sheet should be painted with heat resistant and anti-corrosive paint. iii. Internal surface of incinerator should be line with non– cracking refractory bricks made of ceramics or concrete to withstand the temperature of 1400 oC, furthermore bricks must be backed by thermal insulation and have thickness in between 220C250 mm. iv. There should be thermal insulation of high performance calcium silicate (Density 230Kg.m-3)to withstand high temperature with flame spread/smoke index not more than 1. v. Refractory and thermal insulation must be designed in robust way so that outer temperature on sheet does not rise above 55– 60 oC even after continuous operation of 12 hours. 3. Primary Chamber i. […]

hospital waste management Incinerator system

Incinerator (hospital waste management system) is a turn-key project which will comprise a  hospital grade incinerator, allied accessories and operation for proper disposal of hospital General medical waste (plastics, gloves and papers) and Infectious waste (blood-soaked bandages, sharps waste, surgical waste, human or body parts, cultures, and swabs).the unit should be of high performance to operated continuously for at-least 12 hours daily. Energy/Fuel Source for incinerator will be Natural Gas based on Pyrolysis with smokeless emission, for ensuring the clean environment system should strictly comply with Environmental Protection Agency (EPA) Pakistan emission standards.   Technical Specifications:   1. Burning Capacity i. Incinerator should be capable to burn waste @ 100 kg / hr in single loading. 2. Construction i.   Packaged type skid mounted dual chamber construction ii. Stainless steel or Mild steel outer with thickness 5mm or more, sheet should be painted with heat resistant and anti-corrosive paint. iii. Internal surface of incinerator should be line with non– cracking refractory bricks made of ceramics or concrete to withstand the temperature of 1400 oC, furthermore bricks must be backed by thermal insulation and have thickness in between 220C250 mm. iv. There should be thermal insulation of high performance calcium silicate (Density 230Kg.m-3)to withstand high temperature with flame spread/smoke index not more than 1. v. Refractory and thermal insulation must be designed in robust way so that outer temperature on sheet does not rise above 55– 60 oC even after continuous operation of 12 hours. 3. Primary Chamber i. […]

Particular Spec for Incinerator

The burner shall have all the necessary controls e.g.Solenoid valves, ignition controls, photo electric cell fuel safety controls, low pressure fuel supply cut-off etc.Weight (kg), please indicate:Secondary ChamberGas Retention Time – 2 SecondsDiesel/LPG/LNG, please indicatePower Supply for Control Box- 220V-240V 50Hz single phaseBurn Rate 250kg/h minimumWeight (kg) please indicate:Secondary ChamberGas Retention Time 2 SecondsFuel Diesel/LPG/LNG, please indicatePower Supply for Control Box 220V-240V 50Hz single phaseMinimum operating temperature 920 °C, please indicate Lot 4 C High Temperature Waste IncineratorItem 13 HTW Incinerator model D Burn Rate – 150kg/hour minimum Weight (kg), please indicate: Secondary Chamber Gas Retention Time 2 Seconds Fuel Diesel/LPG/LNG, please indicate The incinerator shall operate in an automatic manner with all the necessary controls.  These controls are to include safety elements such as flame failure unit, pilot lamps, fuses, starters, overload contactors, ON and OFF switches for burners and fans, combustion chamber temperature indicators for primary and secondary chambers etc. i)  Electric ignition switch ‘ON’ before the oil is suppliedii) Delayed return to re-start position to allow purgingiii) Re-start after temporary electric supply failure iv) Positive safety lock-out in case of flame failure from whatever cause.v) Red signal light on control panel to indicate safety lock outvi) Photo electric protective cell as flame failure device.